Skip to content
Manufacturer · Pune, Maharashtra

Power that holds when the feeder doesn’t.UPS manufacturer in Pune.

Online UPS, servo stabilizers, plating rectifiers and lift inverters — built at our own works on Sinhagad Road and load-bank tested before they ship.

Building in Pune
Since 2016Building in Pune
Units supplied
1000+Units supplied
Product lines
12Product lines
Made in-house
100%Made in-house

Who we build for

Lift OEMs, laser and machining shops, battery manufacture, software, co-operative banking, schools and hospitals — across Pune, Maharashtra and beyond.

12 product lines

What we build

Every range is manufactured and tested in Pune. Configured to order, not picked from a container.

All products
Why buy from a works

Four things a reseller can’t offer

Most UPS sellers in Pune import finished cabinets and add a sticker. A different business, and it shows by year seven.

We build it here

Own winding bay, own fabrication, own assembly. Non-standard ratings without waiting on a container.

Every unit load-tested

Not sampled — every unit, at rated capacity, with the readings shipped in the cabinet.

We service any make

Most of our AMC book is other manufacturers. It is how we find out what actually fails.

Same-day in Pune

Load-down calls attended the same day across Pune and PCMC. 24×7 line for AMC customers.

The catalogue, drawn the way you’d draw it

One protected power path

Source, transfer, conditioning, conversion, load. Tap any block to see that range.

Single-line diagram of a protected power pathMAINS / DG415 V 3φTRANSFER SW10–150 ASTABILIZER±1% outputRECTIFIERPFC > 0.90INVERTER3–200 kVALOADTHDv < 3%BATTERY
  • AC in · sine
  • DC bus · flat
  • Clean AC out · sine
  • Bypass · idle

The AC runs are drawn as a sine and the DC bus as a straight line — that is what double conversion means. Every solid block is something we build in Pune.

See the full catalogue
Before anything leaves

Six tests, every unit

A UPS that powers up has not been tested. This is what each machine goes through, and the readings ship with the cabinet.

Visit the works
  1. 01

    Continuity and insulation

    IR test on every winding, phase rotation verified, all terminations torqued and recorded.

  2. 02

    No-load run

    Output waveform on the scope; frequency and voltage regulation against the design figures.

  3. 03

    Stepped load bank

    25, 50, 75 and 100% of rated capacity on a resistive bank, logged at each step.

  4. 04

    Thermal soak

    Held at rated load until stable, then a thermal scan of the power stage and joints.

  5. 05

    Transfer testing

    Mains to battery, battery to mains, bypass in and out — verified on the scope, not by the panel LED.

  6. 06

    Battery discharge

    Bank discharged at rated load so the backup figure on your certificate is measured, not calculated.

Any make, not only ours

Service and support

UPS failures are gradual: a dried capacitor, a stopped fan, one weak cell in sixteen. Invisible on the front panel.

All services
Service engineer taking meter readings inside a UPS cabinet during a scheduled maintenance visit
Any make

UPS Annual Maintenance Contract

Quarterly preventive visits, an annual battery load test rather than a voltage check, and a breakdown line that answers. Any make — not only ours.

  • Quarterly PM
  • 24×7 breakdown
See the process
Termination and commissioning checks being carried out on a newly installed three phase UPS
Site survey

UPS Installation & Commissioning

From the site survey and cable schedule through battery rack assembly to a witnessed load-bank test and a signed commissioning certificate.

  • Cable schedule
  • Load bank test
See the process
Component level board repair on a UPS inverter card at the Pune works
Any make

UPS Repair & Overhauling

Component-level diagnosis, not board swapping. On site where we can, at the works where the job needs a bench and a load bank.

  • Component level
  • On-site or works
See the process
Engineer retrofitting a new UPS alongside the legacy transformer cabinet it replaces
Any make

UPS Upgradation & Retrofit

A machine that no longer suits the load is not always a machine that needs replacing. Any make — we assess what the existing unit can still carry and upgrade what actually limits it.

  • Capacity & bank
  • Controller retrofit
See the process
Cell by cell voltage readings taken across a UPS battery bank on site in Pune
Discharge test

UPS Battery Testing & Replacement

A float voltage reading tells you a failing cell is fine. A discharge test tells you the truth. We measure delivered capacity and give you the number.

  • Cell-by-cell impedance
  • Safe disposal
See the process
Rental UPS units being unloaded at a customer site in Pune
1–100 kVA

UPS on Rent

Daily, monthly or annual hire from 1 kVA to 100 kVA, with delivery, installation and maintenance included. Useful when the requirement is temporary — or when you want to test before you commit capital.

  • Daily to annual
  • Delivery included
See the process
Old UPS units being collected for buyback against a replacement unit
Any make

Old UPS Buyback & Exchange

A valuation on site, the old unit taken away, and the amount set against a new one. Any make, working or not.

  • Working or not
  • On-site valuation
See the process
Where we work

Pune, and the MIDC belt around it

Supply goes anywhere. We only publish a response time where we can meet it.

Equipment ships worldwide against export documentation. Installation and commissioning outside India are quoted per project, with the site contractor doing the on-site work to our commissioning sheet.

Same day

PunePimpri-Chinchwad 25kmBhosari MIDC 28km

Next business day

Chakan MIDC 45kmRanjangaon MIDC 60kmTalegaonHinjewadi 30km

Supply

Mumbai & Navi MumbaiAhmednagar 120kmNashik 210kmChhatrapati SambhajinagarNagpur 700kmKolhapur & SangliAhmedabad & SanandVadodaraIndore & PithampurDelhi NCRBengaluruChennai & SriperumbudurHyderabad 560kmCoimbatoreKolkata

Send us the load list

Ratings, starting method and the backup time you need. That is enough for a real quotation rather than a price list — we reply within one working day.

5 questions

Common questions

Anything not covered here, call us — most of it is faster to answer on the phone.

01Do you manufacture UPS systems yourself or resell them?

We manufacture. Cabinets, transformers and power-stage assembly are done at our works in Pune, and every unit runs a burn-in cycle on a resistive load bank at rated capacity before dispatch. The test sheet ships with the machine and you are welcome to come and watch the test.

02What capacity range do you build?

Online UPS from 3 kVA to 200 kVA across three series: single-phase in and out to 10 kVA, three-phase in with a single-phase output from 10 to 60 kVA, and three-phase in and out from 10 kVA to 200 kVA. Ratings for the other eight product lines are on their own pages, and anything outside the standard range is built to specification.

03Do you service equipment made by other manufacturers?

Yes. A large part of our AMC and repair work is on other makes. We need the model, rating, year and battery configuration so we can confirm spares availability before committing to a response time.

04Which areas do you cover for installation and service?

Pune and Pimpri-Chinchwad with same-day attendance for load-down calls, and the surrounding MIDC belt — Chakan, Bhosari, Ranjangaon, Talegaon — on a next-business-day standard. Supply goes anywhere in India; service outside Maharashtra is contracted case by case.

05How quickly can you quote?

For a standard product against a stated load, within one working day. For anything needing a single-line diagram or a general arrangement drawing — parallel systems, plating lines, hospital installations — allow three to four days after the site survey.